Principle: laser forward scattering principle
Range: 0-20mg/m3, --50mg/m3(customizable)
Indication wavelength: 650nm
Dimension: 330*380*350mm, probe can be customized according to working conditions
Weight: 40kg(including flame)
Analog output: 4-20mA
Response time: 10s
Detection limit: 0.05mg/m3
Interface: RS485, RS232(optional)
Parameter: Baud rate 57600(default), 8 bit data, 1 stop bit, no parity bit
Protocol: Standard Modbus protocol