Measurement Data |
|
Principle | laser forward scattering principle |
Concentration | 0-10mg/m3, 50mg/m39customized) |
Drift | ±2%F.S. |
Indication error |
±20% |
Response time | 10s |
Detection limit | 0.1mg/m3 |
Laser | Wavelength 650nm,power 5mW,voltage 5V |
Measurement Condition |
|
Gas hunidity | Relative humidity:0-100%RH(non-condensing) |
Gas pressure | -2KPa ~1kPa |
Medium temperature | <300℃ |
Ambient temperature | -20℃~﹢50℃ |
Compressed air | No water,no oil,≥0.4MPa,gas consumption 60L/min |
Input,Output and Interface |
|
Analog output | 4-20mA,maximum load 500Ω |
Interface | RS485,RS232(optional) |
Parameter | baud rate 57600(default),8-bit data,1 stop bit, no parity bit |
Protocol | Standard Modbus protocol, customizable |
General Information | |
Weight | 15kg |
Dimension | 240*250*143.5mm |
Power | 220VAC/200W |